I happen to be working with rigid breadboard type expanded polystyrene within the rim joists and believed the same can be place beneath the sheathing in between the rafter bays, and with any gaps sealed which has a urethane spray foam including Fill and Seal. Is there a quality which makes spray foam acceptable and rigid foam unacceptable?

I haven't got a lot of area earlier mentioned or beneath the roof construction for insulation / venting. Would a flash / batt unvented assembly operate below the single sheathing deck? My insulator has carried out Several of these locally.

1. You must get an engineer To judge the security of your respective 2x4 rafters. "Furring down with 2x2s" does not Increase the potential within your 2x4s to bear the snow load. It's achievable that an engineer will recommend you to sister 2x8s or 2x10s onto your existing 2x4 rafters.

Builders solve this issue by furring down or scabbing on additional framing beneath the rafters to deepen the rafter bays. An additional strategy is to add a layer of cross-hatched 2x4s, sixteen inches on center, put in beneath the rafters."

As your house flexes with changes of temperature It truly is achievable, even very likely that many of the foamed-in air sealing will leak. It'd be worth executing two" of open up mobile foam on the interior aspect of which might be a far more versatile and trusted long term air seal.

Hi John - This job was in Vermont inside of a ten-12 months old household and because the caption implies, the primary perpetrator was leaky can lights while in the cathedral ceiling. But the situation was exacerbated by an hooked up greenhouse, which communicated with the remainder of the property, plus a garments dryer vented to the indoors throughout the Wintertime.

Ventilation channels are developed by installing a fabric that will retain a separation (an air gap) amongst the insulation as well as roof sheathing.

You'll want to seek advice from an electrician about the best way to serve your ceiling electrical packing containers. There are numerous doable alternatives -- some noticeable from the inside, and some concealed by The brand new foam.

  To all of my family members, close friends, and neighbors thank you for your personal assist and problem with all of the excellent foodstuff, playing cards and sort words.

If not, he would not reach refuse to put foam earlier mentioned the sheathing, which would be improved and less expensive than fitting it concerning the beams.

If you decide on to put in open up-cell spray foam in place of closed-mobile spray foam, your roof assembly should be able to dry considerably to the inside. Just make sure that the spray hop over to these guys foam layer is thick more than enough to maintain your rafter bays above the dew point in the Winter season.

You might be correct that this kind of roof assembly will not likely dry to the interior. But it isn't speculated to. I'd personally tape the polyiso -- the tape will not bring about any challenges.

A new standalone immediate vent fuel stove goes in in the far finish in the area beneath the metal box. I determine if we use XPS board, it would have to be pulled again quite a few inches from all-around that space, but I failed to Consider it might avert me from working with XPS solely. Looks like Roxul is a lot less of a problem concerning warmth/fire.

I haven't got experience building in the Carribbean or developing metal properties, so I'm not the most beneficial human being to remark. But here are a few reflections: